A Complete Guide to Electromagnetic Compatibility (EMC) in Electric Motors

When developing industrial equipment, the motor EMC performance can affect system stability, certification, and your costs. Motors with good EMC performance can avoid signal interference, control failures, and certification risks. This article will comprehensively introduce motor EMC and help you select the suitable motor for EMC-sensitive applications.

What Is Motor EMC?

Motor EMC (electromagnetic compatibility) refers to the ability of a motor to operate normally in its electromagnetic environment without generating electromagnetic interference (EMI) exceeding the permitted limits, nor being adversely affected by external electromagnetic interference.

Electric motor EMC involves both electromagnetic emissions generated by the motor and its immunity to electromagnetic disturbances.

motor EMC

Why Is EMC Important for Electric Motors?

Prevent Interference With Other Electronics

Motors typically operate in conjunction with controllers, encoders, sensors, and communication devices. For example, PWM-driven motors generate high-frequency electrical disturbances during high-speed switching operations. These disturbances propagate through electrical connections and can interfere with nearby electronics.

Good electric motor EMC performance helps reduce risks such as encoder malfunctions, unstable sensor signals, and communication interference caused by motor EMI.

Maintain Reliable Operation of Motors and Systems

EMC includes both electromagnetic emission and immunity. Good EMC is capable of preventing faults in the motor itself and also keeps stable operation of the entire equipment.

Reduce the Risk of EMC Test Failures

If you are developing equipment for industrial or international markets, particularly for customers in EU countries, EMC performance is usually a part of the product compliance process. Depending on the device application, driver configuration, and target market, relevant requirements may involve standards such as IEC 61800-3 and IEC 61000 series.

Considering electric motor EMC in advance during product design and motor selection can help you identify potential interference issues before formal EMC testing, thereby reducing the risk of later redesign or repeated verification.

Reduce Later System Rectification

When EMC issues are discovered after the motor is integrated into the equipment, you usually need to investigate many aspects such as the motor structure, drive switches, cable length, shielding, grounding, and PCB layout. This makes it difficult for you to determine the root cause of the interference.

Clearly defining the motor’s EMC requirements early enables better integration of the motor into your equipment, reducing the workload of fault troubleshooting and the overall project cost.

What Causes EMC Problems in Motors?

Motor Commutation

For brushed DC motors, mechanical commutation is a common source of electromagnetic noise. When the brush switches between the commutator segments, the rapid change in current causes voltage transients and arcs, resulting in conducted and radiated emissions.

brushed DC motors motor commutation

PWM Switching and Fast Voltage Transitions

BLDC motors, servo motors and other electronically commutated motors are usually used in conjunction with PWM-based drivers. Rapid switching generates high-frequency voltage and current components. Meanwhile, high dv/dt can drive common-mode current through the parasitic capacitance in the motor drive system.

Too Long or Improperly Wired Motor Cables

Motor cables can provide a propagation path for high-frequency disturbances, while also increasing the capacitive coupling between the driver, motor, and ground. The cable length, shielding, wiring, and termination method of the shielding layer can affect the electric motor EMC performance.

Improper Grounding and Shielding

High-frequency common-mode current requires a controlled low-impedance return path. Poor grounding, excessive connection impedance, or improper termination of the cable shielding layer may cause unnecessary current to flow through other parts of the equipment, thereby increasing the risk of interference.

How to Improve Motor EMC Performance?

Optimize the Motor’s Electromagnetic Design

EMC optimization should begin at the electrical and mechanical design stages of the motor. Winding configuration, commutation characteristics, internal motor structure, and parasitic capacitance can all influence electromagnetic emissions and the propagation paths of high-frequency currents.

For DC motor EMC, mechanical commutation is particularly important because arcs generated by brushes can produce electromagnetic noise. Brushed DC motors require a different EMC design approach compared to BLDC motors that use electronic commutation. If your device has high requirements for electromagnetic radiation, choosing a BLDC motor is easier to meet those requirements than a brushed motor.

Optimize Motor Cable and Shielding

When integrating the system, you need:

  • Use appropriate shielded motor cables in the required applications.
  • Route motor UVW power cables separately from sensitive encoder, sensor, and communication cables.
  • Avoid unnecessary excessive lengths of motor cables.
  • Provide proper high-frequency connections for the shielding layer.
  • Keep unshielded cable sections as short as possible.

Especially for robots, AGVs, industrial automation equipment, etc., cable design should be considered during the integration phase.

BLDC motor cable and shielding

Improve Motor Housing and Grounding Design

The motor frame and grounding structure should provide a controllable return path for high-frequency currents. Connecting the motor housing to the appropriate grounding point of the motor driver can provide a lower impedance return path for high-frequency common-mode currents, thereby helping to reduce EMI. You need to consider the motor frame, cable shield, drive, and machine chassis together.

Use Appropriate Filtering and Suppression

When interference persists even after the optimization of motor, cable and grounding designs, filtering and suppression measures can further improve EMC. Depending on the motor and drive architecture, solutions may include an EMI filter for motor, ferrite components, and common-mode chokes.

For brushed DC motors, in appropriate applications, a motor suppression capacitor can reduce the high-frequency electromagnetic emissions generated during commutation. Ferrite components and direct suppression measures at the motor end are also common methods considered when controlling DC motor electromagnetic emissions.

However, you should not simply choose a DC motor filter, capacitor or electric motor suppressor based solely on its stronger filtering capability. The suppression scheme needs to be matched with the controller architecture.

Verify the Improvements Through Testing

The improvement effect of EMC should be verified through testing. Pre-compliance tests can help you determine whether the remaining interference mainly comes from the motor, controller, cables, grounding or filtering before the final product verification.

Motor EMC Testing Methods

Conducted Emissions Testing

Conducted emission testing is used to measure undesirable high-frequency interference propagated through power or motor connection lines. This is particularly important for DC motor EMC and PWM-driven systems, as switching operations introduce high-frequency components onto the connecting cables.

The results of conducted emission testing help you determine whether additional measures such as DC motor EMC filters, common-mode chokes, or other filtering methods are required.

conducted emission test

Radiated Emission Test

Radiated emissions testing evaluates the electromagnetic energy emitted into the surrounding environment. Motor cables, switching circuits, PCB layout, and even the motor’s internal structure can all serve as sources of radiated interference.

BLDC motor radiated emission testing

This test is especially important when you integrate motors into devices containing sensitive sensors, encoders, communication interfaces, or control electronics.

Radiated emission test

Immunity Testing

EMC testing not only focuses on the interference emitted by the equipment itself. It also examines whether the motor drive system can continue to operate normally when subjected to external electromagnetic disturbances. Immunity testing usually includes electrostatic discharge, radiated RF fields, electrical fast transient pulse groups, and other interference.

electrostatic discharge immunity test

Pre-Compliance Testing

Before undergoing formal certification, conducting pre-compliance testing can help you identify potential EMC issues while there is still time for modifications. You can test the motor using the expected controller, cables, grounding layout, and filtering configuration to determine whether the main problem lies with the motor itself or the system integration.

filtering configuration

Motor EMC Standards You Need to Know

EMC compliance is not determined by the motor alone. Most standards focus on the complete system, which includes motors, drivers, cables, controllers, and installation methods. Understanding the relevant standards in advance can help you reduce rectification costs, shorten the certification cycle, and avoid EMC issues during the whole machine verification stage.

IEC 61800-3

IEC 61800-3 is one of the most important EMC standards in variable speed motor systems. It applies to AC and DC drive systems in variable frequency drives, servo systems, and industrial automation equipment. It defines emission and immunity requirements according to different installation environments, such as industrial sites or public low-voltage networks.

If your equipment uses VFDs, servo drives, BLDC controllers, etc., IEC 61800-3 is often a standard that needs to be closely focused on during product development.

IEC 60034 Series

The IEC 60034 series is applicable to rotating motors, covering aspects such as performance, temperature rise, efficiency, and testing. Although it is not a specific EMC standard, it forms the basis for motor design and operation. Meanwhile, understanding these two standards will help you communicate technical requirements more effectively with suppliers.

IEC 61000 Series

The IEC 61000 series includes common immunity tests such as electrostatic discharge (ESD), surge, fast transients (EFT), and radiated immunity. It evaluates whether equipment can continue operating correctly in a real electromagnetic environment.

CISPR 11 / EN 55011

CISPR 11 (EN 55011 in Europe) sets the limits for conducted and radiated emissions for industrial, scientific and medical equipment. If your equipment is used in these environments, you need to pay attention to this standard.

How to Select the Right Motor for EMC-Sensitive Applications?

Define Your EMC Requirements

Firstly, determine the final EMC requirements for your equipment, including the target market, applicable product standards, emission limits and immunity requirements. Providing the manufacturers with the expected applications, required compliance standards and testing conditions in advance will provide them with clear guidance for recommending or customizing the motors.

Match the Motor With the Intended Drive

The motor EMC performance will vary depending on the controller driving it. The motor and the controller should be selected as a combined unit. You should inquire whether the motor has been evaluated together with the controller or an equivalent drive configuration that you expect to use.

Check Motor Construction for Converter Operation

If your motor will be driven by a PWM inverter or other electronic converter, check whether its insulation system and mechanical construction are suitable for converter operation. Depending on the motor size and drive configuration, you may need to discuss with the manufacturer about insulated bearings, shaft grounding, and motor-side filtering.

Consider the Installation and Feedback Environment

The appropriate motor also depends on its operating location, cable length and installation arrangement. If you need the motor to be installed near encoders, sensors, PLCs, communication cables or other sensitive electronic equipment, or if the installation space is limited, its EMC requirements may be more stringent.

Ask for Relevant EMC Test Evidence

For EMC-sensitive applications, you need to know what the manufacturer has actually tested. You should inquire about which projects were tested, whether the controller or equivalent driver you intended to use was used, under what conditions, which standards were applied, and whether the testing was conducted on the motor itself or the complete motor driver system. This allows you to determine whether this motor truly represents your application.

Choose a Motor Manufacturer That Can Customize for EMC

When standard motors fail to meet your EMC requirements, you should look for manufacturers that can assess the winding design, insulation, motor structure, feedback integration, and driver compatibility, rather than relying solely on external EMI filters. You should also confirm whether the manufacturer can modify the motor after initial testing.

As an experienced motor manufacturer, BeUDMKE has motors with EMC test certification. We can also provide customized motor and drive control solutions for EMC-sensitive applications, helping you optimize motor performance and compatibility with your drive system.

FAQ

Does a Brushed DC Motor Have Better EMC Performance Than a BLDC Motor?

Generally, no. Brushed DC motors may generate higher electromagnetic emissions because arcs are produced during the mechanical commutation process. BLDC motors do not have mechanical commutation but introduce switching noise from the electronic driver. For motor EMC, BLDC motors usually have an advantage, but you should still compare the complete motor driver system.

Does a Smaller Motor Have Fewer EMC Problems?

Not necessarily. Motor size alone does not determine motor EMC performance. Motor EMC is influenced more by commutation, winding characteristics, PWM switching, cable configuration, and grounding than motor size. Even small DC motors can generate obvious EMI during operation.

Can a Motor Pass EMC Testing Without an EMI Filter?

Yes. If the emission value remains within the applicable limits under the specified test conditions, then the motor-drive system can pass EMC testing without an external EMI filter. If you want to add a motor EMC filter, you need to first confirm the complete system configuration. It is not always necessary.

How Long Is Too Long for the Cable Connecting the Motor to the Driver?

There is no uniform maximum length for motor cables. The standard length of motor leads is between 0.5 m and 1 m. For BLDC motors, since there are Hall sensors inside the motor, in addition to considering EMC radiation, you should also consider that an excessively long wire may cause interference to the motor’s Hall signals.

For non-inductive brushless motors, a 10 m or even longer cable is allowed. For inductive brushless motors with Hall sensors, typically a 3-5 m length may cause interference to the Hall signals (this depends on the performance of the driver). DC servo motors that support differential signals can allow for longer motor lead lengths.

How to Select X and Y Capacitors for Motor EMC Filtering?

First, look at the connection position of the capacitors and the type of noise. The X capacitor is connected between the lines to suppress differential-mode noise. While the Y capacitor is connected between the line and ground to help handle common-mode noise. When making the selection, you need to consider factors such as operating voltage, safety level, capacitance, leakage current, etc.

Final Thoughts

Reliable motor EMC performance depends on the coordinated operation of motor, driver, cable, grounding, and testing. If you are developing an EMC-sensitive application, please feel free to contact our motor engineers to discuss your motor specifications and application requirements.

Looking for a reliable partner for motors and drivers in China?

Contact our engineers immediately to get the most suitable motor motion control solution for your equipment now!
Scroll to Top