If the EMI control of the motor itself is inadequate, it will significantly increase the difficulty of the entire terminal equipment passing the EMC certification and testing. Therefore, it is crucial to incorporate EMC considerations at an earlier stage of the design and selection process.
This article will deeply analyze the EMI performance characteristics of various motors, aiming to help you select the right model at the initial stage of the project, thereby effectively reducing the cost of subsequent rectification and avoiding potential equipment failure risks.
What Is EMI?
EMI stands for Electromagnetic Interference, which in simple terms refers to those unwanted noise signals that “show up uninvited” in the circuit. Just like background noise, it can interfere with the normal operation of electronic devices, causing problems such as device crashes, data errors, or unstable performance.
Impacts of EMI
Market access barriers: Products intended for global markets must comply with mandatory regulations and standards such as FCC Part 15 and CISPR requirements. If your product does not meet EMI standards, it cannot pass the certification and enter the market.
Terminal reliability risk: If EMI is not properly controlled, your key equipment will fail, which can lead to legal disputes and damage to brand reputation.
Project cost increase: The EMC issue follows the rule that the later it is addressed, the higher the cost. If the rectification is carried out only during the product design finalization or final testing stage, the cost will be much higher than the preventive investment made in the early design stage.
Conducted and Radiated EMI
EMI is generally classified into two types according to propagation path.
Conductive interference spreads through wires, power lines, and signal cables; while radiated interference does not require a physical medium. It propagates in the air in the form of radio waves and can become significant at higher frequencies.

Why Do Motors Generate EMI?
The generation of EMI by the motor is not caused by a single factor. It is usually due to the following three situations:
Physical Arcing of Commutator and Brush System
However well designed the motor commutation system is, minor sparks or arcs may still occur between the brushes and the commutator. And these sparks have extremely wideband radio-frequency emission characteristics, making them natural sources of interference.
Rapid Current Commutation
Rapid current commutation creates high-frequency transient components. The resulting voltage and current changes can contain significant high-frequency energy. This rapidly changing current is similar to a square wave, and its Fourier spectrum will extend into the radio-frequency range, thereby directly producing EMI.
PWM Switching Noise
Both brushed and brushless DC motors, as well as AC motors powered by electronic motor controllers, can create fast voltage transitions and high-frequency current components that contribute to conducted and radiated EMI.
EMI Characteristics Across Different Motor Types
For different types of motor EMI risks and their main causes, you can refer to the table below. This helps assess EMI hazards in the early stages of project selection and avoid subsequent rectification and rework.
| Motor Type | EMI Risk Level | Main Causes |
| AC Induction Motor (Sine-wave Drive) | Low | Generally, no EMI issues are expected; only a weak power-frequency magnetic field may exist near the motor and its input leads |
| AC Induction Motor (VFD Drive) | High | VFD switching operation generates strong noise; the motor itself acts as the load and may radiate interference. |
| DC Brushed Motor | High | Physical arcing from commutator and brushes (broadband RF emission); sudden commutation current changes (high dv/dt); PWM drive noise |
| DC Brushless Motor (Electronic Commutation) | High | Switching operation of electronic commutation generates EMI (originating from DC voltage switching required to produce a rotating magnetic field) |
| AC/DC Universal Series-wound Motor | High | Mechanical action of brushes and commutator produces arcing and sparks |
EMC Compliance for Motors
The key EMC standards for the motor are as shown in the table below:
| Standard No. | Market / Sector | Applicable Objects |
| FCC Part 15 Subpart B | US Market | Unintentional radiators, including general motor-based equipment |
| CISPR 25 | Automotive Sector | On-board automotive electronics and vehicle-use motors |
| RTCA/DO-160 | Aviation Sector | Avionics and airborne motor-driven equipment |
| MIL-STD-461 | Military Sector | Military equipment, military motor and control systems |
| EN55011 | EU Market | Industrial equipment, industrial motor drive units |
| EN55022 | EU Market | Information-technology equipment, IT peripherals with built-in motors |
Tips: EMC compliance depends on your final product rather than individual components. However, you can choose a motor supplier with system-level EMI support capabilities, which is beneficial for reducing the certification risks of the entire device.
Methods of Motor EMI Suppression
During the product development stage, you can implement noise reduction measures by adopting the following EMI suppression methods. Covering aspects such as hardware layout, component selection, and optimization of the driving algorithm, this method helps meet the EMC compliance requirements for the target market.
Equipotential Bonding
The core principle of this method is low impedance, large contact area, anti-corrosion protection, minimization of loop area, and avoidance of ground loops.
We recommend that in specific applications, you mount the battery housing, power frame, motor driver board, and motor housing on the same metal surface. Alternatively, interconnect them using FE wires and low-impedance braided belts. It is best to install the motor driver close to the motor to minimize cable length and reduce the loop area.

Cable Routing
The wiring methods vary for different cables. For motor cables, you can twist the three-phase wires together to minimize the differential-mode loop inductance. If twisting is not possible, when using parallel wiring, try to keep it as close as possible to the equipotential grounding conductor.
Motor cables need to be kept at a distance from DC input cables, position sensor cables, and communication cables. When sufficient separation cannot be maintained, other cables should be crossed orthogonally with the motor cables instead of being laid in parallel.
For DC input cables, a twisted-pair configuration should be used to reduce loop inductance. Sensor cables, motor thermistor leads, and various communication signal cables should be kept away from motor cables. When wiring, make sure to keep them as close as possible to the equipotential bonding conductor.

Cable Shielding
Apart from cable wiring, you can also use cable shielding to further suppress interference. You can add a shielding layer to the phase lines of the motor to reduce capacitance coupling, and the shielding layer is grounded through an equipotential network.
Shield termination should be selected according to the interface specification, grounding architecture, cable construction, and EMC test results.
For the best effect, connect the shielding layer at both the motor and driver ends using 360° metal joints to enhance the shielding effectiveness; when 360° connection is not possible, directly connect the shielding layer with a conductive ring, grounding clip or screw to the ground plane.
For DC input cables, shielding is used to improve EMC. You ground both the power supply and the driver ends, and select 360° shielded connectors.
For position sensors and thermistor cables, ground the shielding layer at a single point on the driver side to prevent ground loops. For CAN, RS485, and EtherCAT buses, connect the shielding layer at both ends to maintain low-impedance continuous grounding and improve coupling suppression.

Filtering
Motor EMI performance can be further optimized by using filters. When the length of the motor cable exceeds 2 meters, or when the EMC requirements exceed the limit set by the driver’s certification, a common-mode choke should be installed on the motor phase wire and placed close to the driver.
For common-mode noise, you can use common-mode choke coils to suppress it. For differential-mode and high-frequency transient interference, you need to combine the actual circuit topology structure and select appropriate filters, capacitors or ferrite cores to deal with them.
During installation, make sure that the grounding conductor does not pass through the choke. The cable shielding layer should be routed externally, and avoid direct contact between the magnetic core and the grounding plane. The DC cable conditions are consistent with the installation specifications and the phase wires.
Additionally, you can install decoupling capacitors between the motor terminals. This is a common and cost-effective solution that can suppress high-frequency voltage peaks and transient noise generated by brush arcing.

FAQ
What Is the Difference Between EMI, RFI and EMC?
EMI refers to any unwanted electromagnetic disturbance, while RFI specifically refers to electromagnetic noise within the frequency range of 3 kHz to 300 GHz.
EMC describes how a device operates in an electromagnetic noise environment, and it encompasses two dimensions: the device’s ability to tolerate noise and the amount of noise it generates itself.
Is It Possible to Eliminate EMI Completely?
EMI cannot be completely eliminated. However, it can be reduced to an acceptable level through appropriate control techniques, thereby meeting the regulatory limits of the target market and ensuring the reliable operation of the equipment in its intended electromagnetic environment.
What Types of EMI Filters Are Available for Motors?
Motor EMI filters are mainly divided into single-phase filters and three-phase filters. For low-power devices such as household appliances, single-phase filters can be used. However, for high-power motors such as those used in industrial machinery and medical equipment, we recommend three-phase filters instead.
What Are the Benefits of Choosing a Supplier With Strong EMI‑Related Technical Capabilities?
The verified EMI suppression solution can reduce the need for repeated motor EMI testing and rectification, and shorten the development cycle of your product. You can use the recommended specific component models to reduce component selection risk and reduce the complexity of the bill of materials.
What EMI Issues Will Occur When the Product Is Used for Mobile Robots / AGVs?
The EMI sources in mobile robots/AGV systems are quite complex. Power-level MOSFETs, motor bodies, motor cables, communication/sensor signals, and DC power input can all cause interference. Therefore, you need a system-level EMI design.
Final Thoughts
The EMI control of the motor is no trivial matter. Instead of incurring costs during the later rectification process, it is better to choose the right solution at the initial product selection stage. BeUDMKE specializes in providing high-performance and cost-effective customized motors.
During the product design phase, we have incorporated low EMI optimization to help you avoid EMC certification risks from the very beginning. If you need support in project selection or anti-interference design, please contact us at any time to obtain free technical guidance.